Cookies de la web de Omega
Utilizamos cookies en la web. Estas cookies son esenciales para que la web que funcione correctamente. Si sigue sin cambiar la configuración, vamos a suponer que usted está dispuesto a recibir todas las cookies de este sitio web.

Para obtener más información acerca de las cookies, por favor haga clic aquí
Cerrar
Cesta  |  Contacto  | 
En España 800 900 532
Fuera de España(+34) 911 776 121
Layer N Banner

Automated Thermocouple Calibrator

CL541-PLUS

Automated Thermocouple Calibrator | CL541-PLUS

Automated Thermocouple Calibrator

1.565,07 CL541-PLUS

CE
  • Source and Read 4 T/C Types J, K, T AND E Plus mV
  • Easy-to-Read Backlight Display
  • Easily Change T/C Types and Scale
  • Calibrate Quickly With Automatic Output Stepping
  • Comes Protected With a Rugged Rubber Boot
  • Calibrate Directly in Temperature (Deg C or F)
  • Compatible With All Process Instruments
Equipos de calibración de precisión y referencias Ice Point - Ver productos relacionados

Descripción

With the CL541-PLUS you can check and calibrate all your thermocouple instruments and measure thermocouple sensors. Take it without worry into the lab, plant or field. It comes protected with a rubber boot and rugged, low profile switch. Easy to operate even in dark areas with the backlit display. Stop carrying around a millivolt source and thermocouple tables, you can calibrate directly in temperature (°C and °F).

The CL541-PLUS works with the T/Cs you use including types J, K, T and E. Easily set any value quickly to within 0.1° with the adjustable digital potentiometer "DIAL" plus store any three temperatures for instant recall. Calibrate quickly with automatic output stepping. Choose between 2, 3, 5, 11 and 21 steps to automatically increment the output in 100%, 50%, 25%, 10% or 5% of span. Select the step time to match your system from 5, 6, 7, 8, 10, 15, 20, 25, 30 and 60 seconds. Connect directly to the thermocouple inputs of smart transmitters, PLCs, controllers and multichannel recorders and verify their outputs or displays. Measure and trouble shoot thermocouple sensor connections and find broken wires or high resistance junctions. Connect your sensor and the CL541-PLUS automatically measures the thermocouple in degrees C or F.

Specifications (Unless otherwise indicated all specifications are rated from a nominal 3°C, 70% RH)
Accuracy: ±(0.008% of Reading + 0.006 mV)
Cold Junction Compensation: ±0.06°C
Millivolt Range: -13.000 to 80.000 mV Operating Temperature
Range: -25 to 60°C
Relative Humidity Range: 10% ≤RH ≤90% (0 to 35°C), non-condensing; 10% ≤RH ≤70% (35 to 60°C), non-condensing
Dimensions: 143 L x 76 W x 41 mm H
Weight: 340 g (including boot and batteries)
Power: 4 "AA" Alkaline 1.5V (included)
Battery Life: 50 Hours
Low Battery: Low battery indication with nominal 1 hour of operation left
Protection Against Misconnection: Over-voltage protection to 60 Vdc (rated for 30 seconds)
Display: High contrast graphic liquid crystal display. LED backlighting for use in low lit areas.

Indicate
Input Impedance:
>10 Megohms
Open Thermocouple
    Threshold:
10,000Ω nominal
    Pulse: <10 microamp pulse for 300 milliseconds
Normal Mode Rejection: 50/60 Hz, 50 dB
Common Mode Rejection: 50/60 Hz, 120 dB

Source
Output Impedance: < 0.3Ω
Source Current: > 20 mA (drives 80 mV into 10Ω)
Noise: ≤4 microvolts p-p for frequencies of 10 Hz or below

Realizar Pedido(Especifique el número de modelo)
Número de pieza/Desc.
Cant.
Descripción
CL541-PLUS
1.565,07
Stock: 6 semanas
 
Automated thermocouple calibrator
Todos los precios se muestran en EUR
Notas: Comes complete with rubber boot, 1 red and 1 black leads with retractable shield banana plugs and aligator clips, 4 "AA" alkaline batteries, NIST certificate of calibration, carrying case and operator’s manual.
Ordering Example: (1) CL541-PLUS  Automated thermocouple calibrator, €1.565,07