Cookies de la web de Omega
Utilizamos cookies en la web. Estas cookies son esenciales para que la web que funcione correctamente. Si sigue sin cambiar la configuración, vamos a suponer que usted está dispuesto a recibir todas las cookies de este sitio web.

Para obtener más información acerca de las cookies, por favor haga clic aquí
Cerrar
Cesta  |  Contacto  | 
En España 800 900 532
Fuera de España(+34) 911 776 121
Layer N Banner

Mass Flow Device

FMA-7100, FMA-7200 and FMA-7300

Mass Flow Device | FMA-7100, FMA-7200 and  FMA-7300

Mass Flow Device

  • ±1% Full Scale Accuracy
  • ±0.25% of Rate Repeatability
  • Broad Range in a Single Unit to Fit Most Applications
  • Field Selectable Soft Start Eliminates Spoiled Batches
  • Normally Closed Valve
  • Low Pressure Drop
  • Compact Design
  • For Clean, Non-Coating Gases
Caudalímetros másicos electrónicos - Ver productos relacionados

Descripción

Find how a Flow meter works on this link.

OMEGA™ FMA-7000E Mass Flow Controllers accurately measure gases on the basis of mass flow. The flow sensor produces an electrical output signal linear with the flowrate used for indicating, recording, and/or control purposes. It eliminates the need for continuous monitoring and readjustment of gas pressures to provide a stable gas flow. This is accomplished automatically by an electromagnetically actuated flowrate control valve.

OPERATING PRINCIPLE The operating principle of the controller is thermodynamic. A precision power supply directs heat to the midpoint of the sensor tube carrying the flow. On the same tube, equidistant upstream and downstream of the heat input, are resistance temperature measuring elements. With no flow, the heat reaching each temperature element is equal. With increasing flow, the flow stream carries heat away from the upstream element, and carries it towards the downstream element. An increasing temperature difference develops between the two elements and this difference is proportional to the mass flowrate of the gas. A bridge circuit interprets the temperature difference and an amplifier provides the output to the control circuitry as well as a 0-5 Vdc output signal.

SPECIFICATIONS
Accuracy: ±1% FS including linearity at calibration conditions, ±1.5% FS including linearity for flow ranges greater than 20 SLM
Repeatability: ±0.25% of rate
Response Time: <3 second response to within 2% FS final value with a 0 to 100% command step
Set Point Input: 0 to 5 Vdc or 1000Ω potentiometer
Output: 0 to 5 Vdc into 2000Ω minimum load; 3 mV rms max. ripple
Maximum Pressure: 1500 psig (Note: Additional charge for pressures >999 PSI). Pressure drop 5 to 50 psid
Temperature Range: 4 to 66°C(40 to 150°F) ambient and gas
Temp. Sensitivity:
    Zero: < ±0.075% FS per °C
    Span: <±1.0% FS shift over 10 to 50°C (50 to 122°F) range
Power Supply Sensitivity: ±0.09% FS per % power supply voltage variation Mounting Attitude Sensitivity: ±0.5% maximum FS deviation after zeroing
Leak Integrity: 1 x 10-9 Atm. scc/sec helium
Control Range: 50 to 1
Pressure Sensitivity: ±0.03% per psi up to 200 psig (N2)
Power: +15 Vdc at 35 mA DC, -15 Vdc at 180 mA dc, 3.5 watts power consumption
Wetted Parts: 316 and 430SS, FKM
Connections: ¼" stainless steel compression fittings
Electrical Connections: Card edge, 20 terminals, gold over low stress nickel-plated copper
Accessories Included: Mating connector with 1.5 m (5') ribbon cable model. Easy connector/cable assemblies available


Specifiy inlet/outlet pressures in order comments. For set-up/calibrations involving pressures over 999 PSI add £375 to the price.

Realizar Pedido(Especifique el número de modelo)
Número de pieza/Desc.
Cant.
Descripción
FMA-7102E-(*)
Consult Sales  
Stock: 
 
 
mass flow meter, 0 to 50 SCCM max range. Specify inlet/outlet pressure in order comments. NB: Additional charge of £375 for >999 psi

Ordenar por número de referencia

Número de pieza
Cant.
Número de pieza
Cant.


Todos los precios se muestran en EUR
Notas: Comes complete with connector and operator's manual.

Specifiy inlet/outlet pressures in order comments. For set-up/calibrations involving pressures over 999 PSI add £375 to the price.

Calibrations done at ambient (20C/70F) temperature only.

All models are custom, consult specification page for a complete product description and list of available models.

We noticed you are from the US. Visit your local site for regional offers and live support.