Cookies de la web de Omega
Utilizamos cookies en la web. Estas cookies son esenciales para que la web que funcione correctamente. Si sigue sin cambiar la configuración, vamos a suponer, que usted está dispuesto a recibir todas las cookies de este sitio web. Para obtener más información acerca de las cookies, por favor haga clic aquí.
Cesta  |  Contacto  | 
800 900 532  | 
Tel. gratuito800 900 532
Fuera de Españ(+34) 911 776 121

Su única funte para la Medición y Control de procesos

OMEGA-FLO® PVC Solenoid Valves for Corrosive Applications, 1/2 to 2 NPT

SV-10 Series

SV-10 Series:OMEGA-FLO® PVC Solenoid Valves for Corrosive Applications, 1/2 to 2 NPT

  • Ideal for Corrosive or Ultra-Pure Processes
  • Single Power Operation
  • Simple Installation
  • Low-Noise Levels
  • Tight Shut-Off
  • Manual Override Standard
  • Normally Closed
Válvulas - Ver productos relacionados


The SV-10 Series solenoid valves for corrosive applications use only plastic or elastomeric materials: PVC for the body, Buna-N, EPDM, and FKM for isolating and main diaphragms, and a fully epoxy-encapsulated pilot solenoid actuator. The pilot actuator uses the pivoted armature design, which hermetically isolates the fluid medium from the armature. The magnetic forces generated are optimized mechanically using the lever principle. The design of these valves reduces noise and the likelihood of water hammer. The main seat seal is a stable, long-lasting flat diaphragm that provides a tight shut-off at the valve seat. SV-10 Series valves are ideally suited for the control of difficult fluids and in aggressive environments such as pure water, demineralized water, seawater, acids of medium concentration, salt solutions, as well as alkaline washing and bleaching lyes.

Mounting Position: Any (preferably coil uppermost)
Material: PVC Body and internals
Max Ambient Temp: 40°C (104°F)
Max Viscosity: Approx. 2.3 x 10-4ft2/s
Coil Voltage: 120 Vac
Voltage Tolerance: ±10%
Power Consumption (in Warm State):
   AC: 20 VA (inrush); 11 VA/5 W (hold)
   DC: 5 W
Opening Time: 100 to 800 ms
Closing Time: 1000 to 4000 ms
Response times are measured at nominal pressure of 85 psi using water and depend on orifice and operation of the valve as well as on pressure and viscosity of the medium.
Cycling Rate: Approx. 10 to 50 cpm
Duty Cycle: Continuous (100%)
Electrical Connection: F-type connector
Realizar Pedido(Especifique el número de modelo)
Número de pieza/Desc.
Stock: 1 semana  
* 1 NPT, 1" orifice, Cv = 16.3, 7-85 psi range
RoHS compliant
1-1/4 NPT, 1-1/4" orifice, Cv = 18.6, 7-85 psi range
RoHS compliant
Stock: 1 semana  
2 NPT, 2" orifice, Cv = 41.9, 7-85 psi range
RoHS compliant
Notas: Comes complete with operator's manual.

Standard valves are normally closed, 120 VAC.