Cookies de la web de Omega
Utilizamos cookies en la web. Estas cookies son esenciales para que la web que funcione correctamente. Si sigue sin cambiar la configuración, vamos a suponer que usted está dispuesto a recibir todas las cookies de este sitio web.

Para obtener más información acerca de las cookies, por favor haga clic aquí
Cerrar
Cesta  |  Contacto  | 
En España 800 900 532
Fuera de España(+34) 911 776 121
Layer N Banner

Discontinued

LVR51

 | LVR51

  • Stainless Steel Construction for a Full Range of Chemically Compatible Liquids
  • Ideal for Use in Chemicals with a Specific Gravity of 0.75 or Greater
  • Rugged Enclosure Rated NEMA-4X for General Purpose or NEMA-7 for Hazardous Areas
  • Continuously Monitor Liquid Levels with Proportional 4-20 mA Output

Descripción

A single float is attached to a stainless steel rod, which is installed through the top of the tank. Internal to the rod is a series of reed switches designed to open and close as the float changes with the liquid level. The internal magnets within the float will open or close the reed switches in a “2-3-2 at-a-time” sequence, which enables the transmitter to provide accurate level indication. With every movement of the float, either one additional switch closes or opens.

SPECIFICATIONS
Range: 12.7 cm to 1.8 m (5" to 72")
Accuracy: 6.35 mm (0.25") over span in water
Specific Gravity: 0.75 minimum
Orientation: ±30° from vertical
Supply Voltage:
    LVR50-PP Series: 10 to 30 Vdc
    LVR50 Series: 10 to 40 Vdc
Loop Resist.: 600Ω @ 24 Vdc
Signal Output: 4 to 20 mA, two-wire
Signal Invert: 4 to 20 or 20-4 mA
Process Temp.: -40 to 149°C (-40 to 300°F)
Electronic Temp.: -40 to 71°C (-40 to 160°F)
Pressure: 300 psi maximum; -15 psig minimum
Enclosure Rating:
    LVR50-PP Series: NEMA 4X (IP65)
    LVR50 Series: NEMA 7 (IP65)
Installed Height:
    LVR50-PP Series: 13.2 cm (5.2")
    LVR50: 15.7 cm (6.2")
Encl. Material:
    LVR50-PP Series: PP, UL94VO
    LVR50 Series: Aluminum
Guide/Float Mat.: 316 SS
Process Mount: 2 NPT
Conduit Entrance: Single, ½ NPT
Classification:
    LVR50-PP: General purpose
    LVR50 Series: Explosion proof
CE Compliance: EN 50082-2 immunity EN 55011 emission
Approvals: LVR50Series: FM: Class I, Division I, Groups B, C & D; Class II, Groups E, F and G Groups E, F and G
Todos los precios se muestran en EUR
Notas: All units come complete with operator’s manual.
We noticed you are from the US. Visit your local site for regional offers and live support.