Ultra Precise RTD Sensors for Industrial Applications

P-M and P-L Series

Ultra Precise RTD Sensors for Industrial Applications | P-M and P-L Series

Ultra Precise RTD Sensors for Industrial Applications

104,20 P-M-A-1/4-6-0-P-3

  • 100 Ohm DIN Platinum RTDs with Class “A”, 1/3 DIN and 1/10 DIN Accuracies
  • Temperature Range Varies with Cable Selection and Accuracy Class (See Description Below).
  • Available in Two Models:
    Standard Closed End Sensor for Immersion Applcations
    Air/Gas Measurement Sensors with Open Ends and Vent Holes.
  • Probes Available in 6mm, 3mm, 1/8" and 1/4" Diameters.
  • 4-Wire Construction in 6 and 3 mm (1/4 and 1/8") Diameters
  • Both Models are Available As Straight Sheaths or With The Followng Mounting Threads: 1/8, 1/4, 3/8 and 1/2NPT, and 6mm, 8mm and 10mm Sizes
Sondas, elementos y asambleas RTD (PT100) - Ver productos relacionados

Descripción

Omega's line of Ultra-Precise RTD temperature sensors provide customers with a product that offers sensor accuracies that are far tighter than are available in most standard RTD sensors on the market today. These sensors are manufactured using DIN Platinum RTD elements (temperature coefficient = .00385 ohm/ohm/°C) with Class A, Class 1/3DIN or Class 1/10DIN accuracies. This makes Omega's Ultra-Precise RTDs among the most accurate industrial temperature sensors available.

These sensors are available in two styles:
Type P-M style closed ended immersion sensors for use where the sensors will be immersed in a fluid.
Type P-L style exposed element sensors for use in direct contact with air or gasses for more accurate measurement of these substances.

There are four probe diameters available including 3mm, 6mm, 1/8" and 1/4", with lengths starting at 50mm (2") with a number of standard lengths available (see ordering table below). A variety of mounting threads are available including: 6x1mm, 8x1mm, 10x1mm, 1/8NPT, 1/4NPT, 3/8NPT and 1/2NPT (Note: 6mm mounting threads are not available on 6mm diameter probes).
Please note that 1/8" and 3mm diameter probes without threaded fittings and with "-P", "-PS", "-TS", "-GS" and "-S" cables include a transition fitting at the end of the sheath to accommodate the cable diameter. If a transition fitting is not acceptable, then a type "-T" or "-G" cable must be specified.

Please note that the minimum recommended length for 1/10DIN accuracy probes is 6” for 1/4" (150mm for 6mm) diameter probes, and 4” for 1/8” (100mm for 3mm) diameter probes. This is due to the fact that in order to achieve these accuracies all stem conduction effects in the sensor must be eliminated. Also, please note that in order to lab certify 1/10DIN accuracy RTDs, it may be necessary for the probes to be longer than these lengths depending on the test equipment used to perform the certification. Omega can make these products shorter than the recommended lengths, but we cannot guarantee their performance. For 1/3DIN probes, a minimum length of 4.75" applies for 1/4" (120mm for 6mm) probes and 2.38" for 1/8" (60mm for 3mm) diameter probes.

The ultimate temperature range of the sensor is dependent upon both the element accuracy and cable selection as shown below (the tightest temperature range applies):

Temperature Range Examples:

P-M-A-1/8-6-0-T-3 has a Class A Element = -100 to 450°C, and "T" (PFA) Cable = -100 to 250°C, resulting in a sensor temperature range of -100 TO 250°C.

P-M-1/10-1/4-9-1/2-P-3 has a 1/10DIN Element = 0 to 100°C, and a P (PVC) Cable = -29 to 100°C, resulting in a sensor temperature range of 0 to 100°C.

Accuracy Specifications:
Class A= ±(0.15 + 0.002 |t| )°C From -100 to 450°C
Class 1/3DIN = ±1/3 (0.3 + 0.005 |t| )°C From -50 to 250°C
Class 1/10DIN = ±1/10 (0.3 + 0.005 |t| )°C From 0 to 100°C

Cable Options:
PVC Insulated ("P") and PVC Insulated and Shielded ("PS") Cables -29 to 100°C.
PFA Insulated ("T") and PFA Insulated and Shielded ("TS) Cables: -100 to 250°C.
Fiberglass Insulated ("G") and Fiberglass Insulated and Overbraided ("GS") Cables: -73 to 400°C.
Silicone Insulated ("S") Cables: -50 to 200°C.

Your Ultra-Precise RTD sensor can be combined with a wide variety of equipment and accessories to construct an entire measurement and control system. Select from a wide variety of controllers, panel meters, transmitters, recorders and data loggers to monitor, control and record your process. See the links below to view a sampling of our complimentary products, or call our Customer Service Representatives and Application Engineers for assistance in selecting the right products for your needs.
Realizar Pedido(Especifique el número de modelo)
Número de pieza/Desc.
Cant.
Descripción
Immersion Sensor Models:
P-M-1/10-1/4-4-0-P-3
148.77
Stock: 1 semana
 
Accuracy: 1/10 DIN. Sheath: Closed End, 4" Long 1/4" Diameter, No Threaded Fitting. Leadwire: 3 Feet (1m), PVC Insulated.
P-M-1/10-1/8-6-0-P-3
184.82
Stock: 1 semana
 
Accuracy: 1/10 DIN. Sheath: Closed End, 6" (150mm) Long 1/8" Diameter, No fitting. Leadwire: 3 Feet (1m), PVC Insulated
P-M-1/10-1/4-6-0-P-3
158.16
Stock: 6 semanas
 
Accuracy: 1/10 DIN. Sheath: Closed End, 6" (150mm) Long 1/4" Diameter, No fitting. Leadwire: 3 Feet (1m), PVC Insulated
P-M-1/10-1/4-6-0-P-15
176.95
Stock: 6 semanas
 
Accuracy: 1/10 DIN. Sheath: Closed End, 6" (150mm) Long 1/4" Diameter, No fitting. Leadwire: 15 Feet (4.5 meters), PVC Insulated
P-M-1/3-1/8-6-0-T-3
144.09
Stock: 6 semanas
 
Accuracy: 1/3DIN. Sheath: Closed End, 6" (150mm) Long 1/8" Diameter, No Fitting. Leadwire: 3 Feet (1m), PFA Insulated.
P-M-1/3-1/8-6-3/8-T-3
Consult Sales  
Stock: 
 
 
Accuracy: 1/3DIN. Sheath: Closed End, 6" (150mm) Long 1/8" Diameter, 3/8 NPT Fitting. Leadwire: 3 Feet (1m), PFA Insulated.
P-M-A-1/4-3-1/2-PS-12
139.50
Stock: 6 semanas
 
Accuracy: Class “A”. Sheath: Closed End, 6" (150mm) Long 1/4" Diameter, 1/2 NPT Fitting. Leadwire: 12 Feet (3.6 meters), PVC Insulated, Shielded.
P-M-A-1/4-6-0-T-3
98.70
Stock: 6 semanas
 
Accuracy: Class “A”. Sheath: Closed End, 6" (150mm) Long 1/4" Diameter, No Mounting Fitting. Leadwire: 3 Feet (1m), PFA Insulated.
P-M-A-1/4-6-1/2-TS-3
150.51
Stock: 6 semanas
 
Accuracy: Class “A”. Sheath: Closed End, 6" (150mm) Long, 1/2 NPT Fitting. Leadwire: 3 Feet (1m), PFA Insulated, Shielded.
P-M-A-1/8-6-1/2-TS-5
180.87
Stock: 6 semanas
 
Accuracy: Class “A”. Sheath: Closed End, 6" (150mm) Long 1/8" Diameter, 1/2 NPT Mounting Fitting. Leadwire: 5 Feet (1.5 meters), PFA Insulated & Shielded.
Exposed Air/Gas Models
P-L-1/10-1/8-6-0-T-3
198.48
Stock: 1 semana
 
Accuracy: 1/10 DIN. Sheath: Air Sensor, 6" (150mm) Long 1/8" Diameter, No Mounting Fitting. Leadwire: 3 Feet (1 meter), PFA Insulated Cable
P-L-1/10-1/8-6-1/8-T-3
216.67
Stock: 6 semanas
 
Accuracy: 1/10 DIN. Sheath: Air Sensor, 6" (150mm) Long 1/8" Diameter, 1/8" NPT Mounting Fitting. Leadwire: 3 Feet (1 meter), PFA Insulated Cable
P-L-1/10-1/4-6-0-P-3
157.13
Stock: 6 semanas
 
Accuracy: 1/10 DIN. Sheath: Air Sensor, 6" (150mm) Long 1/4" Diameter, No Mounting Fitting. Leadwire: 3 Feet (1 meter), PVC Insulated Cable
P-L-1/3-1/8-6-3/8-T-3
Consult Sales  
Stock: 
 
 
Accuracy: 1/3 DIN. Sheath: Air Sensor, 6" (150mm) Long 1/8" Diameter, 3/8 NPT Mounting Fitting. Leadwire: 3 Feet (1 meter), PFA Insulated
P-L-A-1/8-6-0-T-3
126.37
Stock: 6 semanas
 
Accuracy: Class “A”. Sheath: Air Sensor, 6" (150mm) Long 1/8" Diameter, No Mounting Fitting. Leadwire: 3 Feet (1 meter), PFA Insulated Cable.
P-L-A-1/8-6-1/8-T-3
Consult Sales  
Stock: 
 
 
Accuracy: Class “A”. Sheath: Air Sensor, 6" (150mm) Long 1/8" Diameter, 1/8 NPT Mounting Fitting. Leadwire: 3 Feet (1 meter), PFA Insulated Cable.
P-L-A-1/4-6-1/4-T-6
€140.22
Stock: 6 semanas
 
Accuracy: Class “A”. Sheath: Air Sensor, 6" (150mm) Long 1/4" Diameter, 1/4 NPT Mounting Fitting. Leadwire: 6 Feet (2 meters), PFA Insulated.
P-L-A-1/4-6-0-P-3
€95.61
Stock: 6 semanas
 
Accuracy: Class “A”. Sheath: Air Sensor, 6" (150mm) Long 1/4" Diameter, No Mounting Fitting. Leadwire: 3 Feet (1 meter), PVC Insulated Cable.
Most Popular Accessories
OM-EL-2-12BIT
Consult Sales  
Stock: 
 
 
Easy Log 12 BIT Portable RTD Data Logger
OM-DAQPRO-5300-UNIV
€1,173.97
Stock: En stock
 
Portable Handheld Datalogger
OM-CP-RFRTDTEMP2000A
€367.89
Stock: 1 semana
 
Precision RTD Recorder and Wireless Transmitter
DP460-RTD
Consult Sales  
Stock: 
 
 
Economical Temperature Meter
CL27
Consult Sales  
Stock: 
 
 
High Precision Handheld Calibrator/Thermometer
CN1A-RTD
€272.88
Stock: 1 semana
 
1/16 DIN On-Off LCD Temperature Controller
DRF-RTD-115VAC-0/200C-4/20
Consult Sales  
Stock: 
 
 
RTD Input Signal Conditioner
Todos los precios se muestran en EUR
Notas: For longer sheath length, change "-6" in model to desired length in inches and add $1 per inch to price when longer than 8". For Silicone Rubber insulated cable, change "-P", "-T" or "-G" to "-S" in the model number and use PFA pricing. For longer cable lengths, change "-3" to desired length in feet and add $0.40/ft for PVC, $0.95/ft for PFA or Silicone Rubber and $1.50/ft for fiberglass. For shielding on PVC, PFA or Fiberglass insulated cables, change "P", "T" or "G" to "PS", "TS" or "GS" and add $0.25 per foot to the price. Mounting threads also available in 1/4 NPT, 3/8 NPT and 1/2 NPT at the same price. 1/8" diameter sensors without threaded fittings and with "P", "PS", "TS", "GS" and "S" cables include a transition fitting at the end of the sheath. For metric diameter probes multiply price/ft adders by 3.28 and round to the nearest $0.10.
Ordering Example: (1) P-M-1/10-1/4-6-0-P-3 100 Ohm, 1/10 DIN Platinum RTD with a 1/4, €158.16

Referencia del fabricante

Construya su Referencia Abajo
Descripciones de las opciones:


(1) Probe Type Seleccione:
M para Closed Ended Immersion Style
L para Open Ended Air/Gas Direct Exposure Style

(2) Sensor Accuracy Seleccione:
A para Class A
1/3 para Class 1/3DIN
1/10 para Class 1/10DIN

(3) Probe Diameter Seleccione:
1/8 para 1/8 inch Diameter
1/4 para 1/4 inch Diameter
M30 para 3mm Diameter
M60 para 6mm Diameter (Not valid with M6 Mounting Thread)

(4) Probe Length Seleccione:
6 para 6 inches Long
9 para 9 inches Long
12 para 12 inches Long
18 para 18 inches Long
24 para 24 inches Long
150 para 150mm Long
225 para 225mm Long
300 para 300mm Long
450 para 450mm Long
600 para 600mm Long

(5) Mounting Thread Seleccione:
0 para No Mounting Thread
1/8 para 1/8NPT Thread
1/4 para 1/4NPT Thread
3/8 para 3/8NPT Thread
1/2 para 1/2NPT Thread
M6 para 6x1mm Thread
M8 para 8x1mm Thread
M10 para 10x1mm Thread

(6) Cable Construction Seleccione:
P para PVC Insulated & Jacketed (100°C Max)
T para PFA Insulated & Jacketed (250°C Max)
G para Fiberglass Insulated & Jacketed (400°C Max)
S para Silicone Rubber Insulated and Jacketed (200°C max)
PS para PVC Insulated & Jacketed with Shield (100°C Max)
TS para PFA Insulated & Jacketed w/Shield (250°C Max)
GS para Fiberglass Insulated & Jacketed w/SST Overbraid (400°C Max)

(7) Cable Length Seleccione:
3 para 3 Foot Standard (Standard Dimensions)
1 para 1 meter Standard (Metric Dimensions)
Notas: No todas las combinaciones pueden ser válidas. Verifique en la hoja de especificaciones para números de parte válidos