Cookies de la web de Omega
Utilizamos cookies en la web. Estas cookies son esenciales para que la web que funcione correctamente. Si sigue sin cambiar la configuración, vamos a suponer que usted está dispuesto a recibir todas las cookies de este sitio web.

Para obtener más información acerca de las cookies, por favor haga clic aquí
Cerrar
Cesta  |  Contacto  | 
En España 800 900 532
Fuera de España(+34) 911 776 121
Layer N Banner

Preamplified Alpha® Electrodes

PHE-6300, PHE-5300, PHE-2114 and PHE-1304

Preamplified Alpha® Electrodes | PHE-6300, PHE-5300, PHE-2114 and PHE-1304

Preamplified Alpha® Electrodes

132,11 PHE-1304-EB

  • Interfaces Directly with Most Instrumentation that Accepts mV Input Signal
  • Signal can be Run Up to 305 m (1000')
  • Power Supply Available in Three Styles
Electrodos de pH de campo y laboratorio - Ver productos relacionados

Descripción

Find how a pH Meter works on this link.

OMEGA Engineering offers pH electrodes with integral preamplifiers for laboratory or industrial applications. These electrodes can interface directly with equipment that accepts a millivolt input signal with a 10 k½ or greater input impedance, such as a data acquisition interface or multimeter. The preamplifier converts the high impedance millivolt signal of the electrode into a low impedance signal, enabling the signal to be run up to 305 m (1000') without signal loss. The electrode is supplied with 1 to 3 m (3 to 10') of coaxial cable, depending on the model. If longer cable lengths are required, simply splice on extension cable.

These preamplified electrodes are available in a variety of styles and can interface with any pH meter, controller, transmitter, multimeter or data acquisition system with a one-to-one unity gain.

An accompanying power supply is available in three styles: an encapsulated battery design, an external battery style, and a style for use with an external dc power source.

Model No. Description
PHE-1304-(*)Combination gel-filled, epoxy-bodied, general purpose laboratory
pH electrode. pH range 0 to 12, temp. 0 to 80°C (32 to 176°F).
PHE-2114-(*)Combination general purpose, large bulb, refillable glass pH
electrode. pH range 0 to 13, temp. 0 to 1000°C (32 to 1832).
PHE-5311-10-(*)Industrial in-line combination, general purpose, gel filled, pH
electrode, Kynar housing, 1/2" MNPT threading, insertion length 1".
10' of cable standard. pH range 0 to 13, temp. range
-5 to 100°C. (23 to 212°F). Dimensions: 127 x 25 mm (5 x 1").
PHE-5411-10-(*)Industrial in-line combination double junction electrode. MNPT
threading, insertion length 1". 10' of cable standard. pH range 0 to
13, temp. range -5 to 100°C (23 to 212°F).
Dimensions: 127 x 25 mm (5 x 1").
PHE-5316-10-(*)Industrial in-line combination, general purpose, gel-filled, pH
electrode, CPCV housing, 3/4" MNPT threading, 2" insertion length.
10' cable standard. pH range 0 to 13, temp. range
-5 to 80°C (23 to 176°F). Dimensions: 168 x 25 mm (6.6 x 1").
PHE-6351-10-(*)Industrial submersible, combination, general purpose,
gel-filled, pH electrode. Electrode potted in 36" ABS pipe.
10' cable standard. pH range 0 to 13, temp. range 0 to 80°C
(32 to 176°F). Dimensions: 28 x 914 mm (1.1 x 36").
PHE-6451-10-(*)Industrial submersible, combination, double junction,
gel-filled, pH electrode. Electrode potted in 36" ABS pipe.
10' cable standard. pH range 0 to 13, temp. range
0 to 80°C (32 to 176°F). Dimensions: 28 x 914 mm (1.1 x 36").
* Specify power option (see table) and add additional cost to price of electrode:
“-EB” ($60), “-PB” ($60), or “-NB” ($50).
Realizar Pedido(Especifique el número de modelo)

¿Qué compraron otras personas?: Cuando se muestre este icono, haga clic para expandir una lista de los productos que otras personas adquirieron al comprar ese modelo.

Número de pieza/Desc.
Cant.
Descripción
Example part numbers are shown below. For additional configurations see the Part Number Builder below this table.
Click to expand/minimize a list of what others bought with thePHE-1304
PHE-1304
55.01
Stock: 4 semanas
 
Combination gel-filled, epoxy-bodied, general purpose laboratory pH electrode. pH range 0 to 12 temp. 0 to 80°C (32 to 176°F)
  
PHE-1304-EB
132.11
Stock: 6 semanas
 
Pre-amp electrode with replaceable external battery pack
  
PHE-1304-NB
116.68
Stock: 6 semanas
 
Pre-amp electrode, requires external DC power supply
  
PHE-1304-PB
Consult Sales  
Stock: 
 
 
Pre-amp electrode with battery encapsulated in the cap. Battery can not be replaced.
  
PHE-2114
119.15
Stock: 6 semanas
 
Combination, general purpose, large bulb, refillable glass pH electrode. pH range 0 to 13, temp. 0 to 1000°C (32 to 1832°F)
  
PHE-2114-EB
Consult Sales  
Stock: 
 
 
Pre-amp electrode with replaceable external battery pack
  
PHE-2114-NB
Consult Sales  
Stock: 
 
 
Pre-amp electrode, requires external DC power supply
  
PHE-2114-PB
Consult Sales  
Stock: 
 
 
Pre-amp electrode with battery encapsulated in the cap. Battery can not be replaced.
  
PHE-5311-10
161.19
Stock: 6 semanas
 
Industrial in-line combination, general purpose, gel-filled, pH electrode, PVDF housing, 1/2 MNPT threading, insertion length 1". pH range 0 to 13, temperature range -5 to 100°C (23 to 212°F)
  
PHE-5311-10-EB
243.05
Stock: 6 semanas
 
Pre-amp electrode with replaceable external battery pack
  
PHE-5311-10-NB
207.95
Stock: 6 semanas
 
Pre-amp electrode, requires external DC power supply
  
PHE-5311-10-PB
Consult Sales  
Stock: 
 
 
Pre-amp electrode with battery encapsulated in the cap. Battery can not be replaced.
  
PHE-5411-10
195.20
Stock: 6 semanas
 
Industrial in-line combination double junction electrode, MNPT threading, insertion length 1". pH range 0 to 13, temperature range -5 to 100°C (23 - 212°F)
  
PHE-5411-10-EB
Consult Sales  
Stock: 
 
 
Pre-amp electrode with replaceable external battery pack
  
PHE-5411-10-NB
258.15
Stock: 6 semanas
 
Pre-amp electrode, requires external DC power supply
  
PHE-5411-10-PB
Consult Sales  
Stock: 
 
 
Pre-amp electrode with battery encapsulated in the cap. Battery can not be replaced.
  
PHE-5316-10
144.83
Stock: 6 semanas
 
Industrial in-line combination, general purpose, gel-filled pH electrode, CPCV housing, 3/4 MNPT threading, 2" insertionlength. pH range 0 to 13, temperature range -5 to 80°C (23 to 176°F)
  
PHE-5316-10-EB
Consult Sales  
Stock: 
 
 
Pre-amp electrode with replaceable external battery pack
  
PHE-5316-10-NB
Consult Sales  
Stock: 
 
 
Pre-amp electrode, requires external DC power supply
  
PHE-5316-10-PB
Consult Sales  
Stock: 
 
 
Pre-amp electrode with battery encapsulated in the cap. Battery can not be replaced.
  
PHE-6351-10
180.58
Stock: 6 semanas
 
Industrial subersible, combination, general purpose gel-filled, pH electrode. pH range 0 to 13, temperature range 0 to 80°C (32 to 176°F)
  
PHE-6351-10-EB
Consult Sales  
Stock: 
 
 
Pre-amp electrode with replaceable external battery pack
  
PHE-6351-10-NB
245.40
Stock: 6 semanas
 
Pre-amp electrode, requires external DC power supply
  
PHE-6351-10-PB
Consult Sales  
Stock: 
 
 
Pre-amp electrode with battery encapsulated in the cap. Battery can not be replaced.
  
PHE-6451-10
211.09
Stock: 6 semanas
 
Industrial submersible, combination, double junction, gel-filled, pH electrode. pH range 0 to 13, temperature range 0 to 80°C (32 to 176°F)
  
PHE-6451-10-EB
Consult Sales  
Stock: 
 
 
Pre-amp electrode with replaceable external battery pack
  
PHE-6451-10-NB
Consult Sales  
Stock: 
 
 
Pre-amp electrode, requires external DC power supply
  
PHE-6451-10-PB
Consult Sales  
Stock: 
 
 
Pre-amp electrode with battery encapsulated in the cap. Battery can not be replaced.
Accessories
  
EB-SPARE
29.00
Stock: 7 semanas
 
Spare battery pack for -EB option.
Click to expand/minimize a list of what others bought with thePHE-DPS
PHE-DPS
75.96
Stock: 6 semanas
 
±3 Vdc power supply to operate preamplified electrodes, input 115 Vac
Todos los precios se muestran en EUR
Notas: Specify power option and add additional cost to price of electrode: "-EB" ($60), "-PB" ($60), or "-NB" ($50).

Referencia del fabricante

Construya su Referencia Abajo
Descripciones de las opciones:


(1) Code in Part Number Seleccione:
1304 para code 1304
2114 para code 2114
5311-10 para code 5311-10
5316-10 para code 5316-10
6351-10 para code 6351-10
6451-10 para code 6451-10

(2) Code in Part Number Seleccione:
Nada (dejar en blanco)
-EB para Replaceable external battery pack
-PB para Battery encapsulated in the cap of the electrode. Battery life approximately one year. Battery cannot be replaced
-NB para Requires external dc power supply of ±1.5 Vdc to ±9 Vdc
Notas: No todas las combinaciones pueden ser válidas. Verifique en la hoja de especificaciones para números de parte válidos
We noticed you are from the US. Visit your local site for regional offers and live support.