Cookies de la web de Omega
Utilizamos cookies en la web. Estas cookies son esenciales para que la web que funcione correctamente. Si sigue sin cambiar la configuración, vamos a suponer que usted está dispuesto a recibir todas las cookies de este sitio web.

Para obtener más información acerca de las cookies, por favor haga clic aquí
Cerrar
Cesta  |  Contacto  | 
En España 800 900 532
Fuera de España(+34) 911 776 121
Layer N Banner

Intrinsically Safe Pressure Transmitters - Metric Models  - NOT CE Compliant

PXM509-IS Series

Intrinsically Safe Pressure Transmitter | High Temperature and Liquid Measurements | PXM509-IS Series

  • High 0.08% Accuracy with NIST Traceable Calibration Certificate
  • 4 to 20 mA Output with FM Intrinsically Safe Rating
  • Solid State Sensor for Long Term Stability
  • 316L SS Wetted Parts and Welded Stainless Steel Construction
  • Shock and Vibration Rated
  • Ruggedized with Secondary Containment System
  • Demountable Electrical Termination
  • User Accessible Trim Pots on Most Models
  • APPLICATIONS
  • Process Control
  • Hydraulic and Pneumatic Systems
  • Natural Gas Compressors
  • Chemical Refineries
  • Oil and Gas
  • Pipeline Measurements
  • Hydrogen (316L SS Wetted Parts Standard)
  • Power Generation
Transductores de presión - Ver productos relacionados

Descripción

The PXM509 intrinsically safe transducers are rugged all stainless steel transducers specifically designed to meet the requirements for use in hazardous locations for all classes and zones.
Features include welded stainless steel construction, user accessible potentiometers, and a demountable electrical termination end. They are designed for rugged industrial applications, and have high shock and vibration ratings and excellent long term stability.
A precision micromachined silicon sensor is at the core, and provides a very stable reading with exceptional high accuracy of 0.08% and a broad compensated range of -29 to 75°C (-20 to 167°F) on most ranges.
Modular construction allows for fast delivery of most configurations and fittings including agency approved models, plus, customized models also can be delivered quickly to suit your exact needs. Models with ½ NPT conduit fitting (PX509C) do not have a demountable termination and trim pots are an extra cost option.
This latest addition of the FM Approved Intrinsically Safe version for Hazardous Locations (available with 4-20 mA output) only further expands the range of applications of this versatile product family.

FM ApprovalsRecognized and respected across the globe, FM Approvals certification assures customers a product or service that has been objectively tested and conforms to the highest national and international standards. Please refer to FM Approvals for downloadable copies of FM Approvals Certificate of Compliance and Installation Control Drawings.

SPECIFICATIONS
Compensated Temperature & Thermal Effects:
Compensated Temperature
    10 inH2O to 5 psi: -17 to 80°C
    15 to 3500 psi: -29 to 80°C
Zero Temperature Shift
    10 inH2O to 5 psi: ±1.0% span
    15 to 3500 psi: ±0.5% span
Span Temperature Shift
    10 inH2O to 5 psi: ±1.0% span
    15 to 3500 psi: ±0.5% span
Over Pressure     10 inH2O: 10 times
    1 psi: 6 times
    2.5 to 500 psi: 4 times
    750 to 3500: 3 times
Containment
    10 inH2O to 5 psi: To 1000 psi
    15 to 750 psi: To 3000 psi
    1000 psi: To 4000 psi
    1500 psi: To 6000 psi
    2500 psi: To 8000 psi
    3500 psi: To 11,000 psi
Absolute/Barometric Pressure Ranges
Over Pressure
    5 psia: 6 times span
    15 to 1000 psia: 4 times span
    1500 to 5000 psia: 7250 psia maximum
Containment
    All Ranges: To 10,000 psi
Gauge/Vacuum/Compound Pressure Ranges
Over Pressure
    10 inH2O: 10 times span
    1 psi: 6 times span
    2.5 to 1000 psi: 4 times span
    1500 to 5000 psi: 7250 psi maximum
Minimum Resistance Between Transducer Body and Any Wire: 100MΩ @ 50 Vdc
Accuracy (Combined Linearity, Hysteresis and Repeatability): ±0.08% BSL maximum (other accuracies available) For conduit (C and CW) zero and span set ±0.5% full scale typical ±1% maximum or set ±1% full scale typical ±2% maximum ranges 2.5 psi and below
Pressure Cycles: 1 million typical
Long Term Stability (1-Year): ±0.1% full scale typical
Supply Voltage: 10 to 28 Vdc
Output: 4 to 20 mA Operating Temperature: -40 to 80°C (-40 to 176°F)
Wetted Material: 316L stainless steel
Bandwidth: DC to 1kHz (typical)
Sensor: Oil filled silicon
Shock: 50 g, 11 msec half sine shock
Vibration: ±20 g
Response Time: <1 msec
RoHS Compliant
Weight: 315 g (11 oz) typical depending upon configuration
Realizar Pedido(Especifique el número de modelo)
Número de pieza/Desc.
Cant.
Descripción
SAMPLING OF POPULAR MODELS SHOWN BELOW; SEE PART NUMBER BUILDER FOR COMPLETE OFFERING
PXM509C-025HGC2IS
Consult Sales  
Stock: 
 
 
2 m cable termination with 1/2 NPT conduit connector, 0 to 25 mb gage pressure range
PXM509C-350HGC2IS
Consult Sales  
Stock: 
 
 
2 m cable termination with 1/2 NPT conduit connector, 0 to 350 mb gage pressure range
PXM509C-001BGC2IS
Consult Sales  
Stock: 
 
 
2 m cable termination with 1/2 NPT conduit connector, 0 to 1 bar gage pressure range
PXM509C-010BGC2IS
866.27
Stock: 7 semanas
 
2 m cable termination with 1/2 NPT conduit connector, 0 to 10 bar gage pressure range
PXM509C-245BGC2IS
Consult Sales  
Stock: 
 
 
2 m cable termination with 1/2 NPT conduit connector, 0 to 245 bar gage pressure range
PXM559-025HGC2IS
Consult Sales  
Stock: 
 
 
M12 connector, 0 to 25 mb gage pressure range
PXM559-350HGC2IS
Consult Sales  
Stock: 
 
 
M12 connector, 0 to 350 mb gage pressure range
PXM559-001BGC2IS
834.18
Stock: 7 semanas
 
M12 connector, 0 to 1 bar gage pressure range
PXM559-050BGC2IS
Consult Sales  
Stock: 
 
 
M12 connector, 0 to 50 bar gage pressure range
PXM559-245BGC2IS
786.31
Stock: 7 semanas
 
M12 connector, 0 to 245 bar gage pressure range
PXM509C-350HAC2IS
Consult Sales  
Stock: 
 
 
2 m cable termination with 1/2 NPT conduit connector, 0 to 350 mb absolute pressure range
PXM509C-001BAC2IS
866.27
Stock: 7 semanas
 
2 m cable termination with 1/2 NPT conduit connector, 0 to 1 bar absolute pressure range
PXM509C-010BAC2IS
Consult Sales  
Stock: 
 
 
2 m cable termination with 1/2 NPT conduit connector, 0 to 10 bar absolute pressure range
PXM509C-100BAC2IS
Consult Sales  
Stock: 
 
 
2 m cable termination with 1/2 NPT conduit connector, 0 to 100 bar absolute pressure range
PXM509C-245BAC2IS
Consult Sales  
Stock: 
 
 
2 m cable termination with 1/2 NPT conduit connector, 0 to 245 bar absolute pressure range
Todos los precios se muestran en EUR
Notas: Comes complete with 5-point NIST traceable calibration.

Referencia del fabricante

Construya su Referencia Abajo
Descripciones de las opciones:


(1) Electrical Termination Seleccione:
09 para Cable with flying leads 2 m (6')
09C para Cable with 1/2 NPT conduit connector (no trim pots not demountable)
09CP para Cable with 1/2 NPT conduit connector and side accessible trim pots
09CW para Submersible cable with 1/2 NPT conduit connector (no trim pots not demountable) 3 m (10')
09CWP para Submersible cable with 1/2 NPT conduit connector and side accessible trim pots (not demountable) 3 m (10')
19 para Mini-Din connector
29 para Bendix twist-lock connector
39 para DIN connector (mating connector not included)
49 para Glass to metal sealed solder pins
59 para M12 connector

(2) Range Seleccione:
025HG para 0 to 25 mb (Gage Pressure Only)
070HG para 0 to 70 mb (Gage Pressure Only)
170HG para 0 to 170 mb (Gage Pressure Only)
350HG para 0 to 350 mb (Gage Pressure Only)
001BG para 0 to 1 bar (Gage Pressure Only)
002BG para 0 to 2 (Gage Pressure Only)
3.5BG para 0 to 3.5 (Gage Pressure Only)
007BG para 0 to 7 (Gage Pressure Only)
010BG para 0 to 10 (Gage Pressure Only)
17.5BG para 0 to 17.5 (Gage Pressure Only)
035BG para 0 to 35 (Gage Pressure Only)
050BG para 0 to 50 (Gage Pressure Only)
070BG para 0 to 70 (Gage Pressure Only)
100BG para 0 to 100 (Gage Pressure Only)
175BG para 0 to 175 (Gage Pressure Only)
245BG para 0 to 245 (Gage Pressure Only)
7BSG para 0 to 7 bar (Sealed Gage Only)
10BSG para 0 to 10 (Sealed Gage Only)
17.5BSG para 0 to 17.5 (Sealed Gage Only)
35BSG para 0 to 35 (Sealed Gage Only)
50BSG para 0 to 50 (Sealed Gage Only)
70BSG para 0 to 70 (Sealed Gage Only)
100BSG para 0 to 100 (Sealed Gage Only)
175BSG para 0 to 175 (Sealed Gage Only)
245BSG para 0 to 245 (Sealed Gage Only)
350HA para 0 to 350 mb (Absolute Pressure Only)
001BA para 0 to 1 bar (Absolute Pressure Only)
002BA para 0 to 2 (Absolute Pressure Only)
3.5BA para 0 to 3.5 (Absolute Pressure Only)
007BA para 0 to 7 (Absolute Pressure Only)
010BA para 0 to 10 (Absolute Pressure Only)
17.5BA para 0 to 17.5 (Absolute Pressure Only)
035BA para 0 to 35 (Absolute Pressure Only)
050BA para 0 to 50 (Absolute Pressure Only)
070BA para 0 to 70 (Absolute Pressure Only)
100BA para 0 to 100 (Absolute Pressure Only)
175BA para 0 to 175 (Absolute Pressure Only)
245BA para 0 to 245 (Absolute Pressure Only)
025HCGB para ±25 mbar (Compound Gage Range Only)
070HCGB para ±70 mbar (Compound Gage Range Only)
170HCGB para ±170 mbar (Compound Gage Range Only)
350HCGB para ±350 mbar (Compound Gage Range Only)
001BCGB para ±1 bar (Compound Gage Range Only)
025HV para 0 to -25 mbar (Vacuum Range Only)
070HV para 0 to -70 mbar (Vacuum Range Only)
170HV para 0 to -170 mbar (Vacuum Range Only)
350HV para 0 to -350 mbar (Vacuum Range Only)
001BV para 0 to -1 bar (Vacuum Range Only)
1100HB para 0 to 1100 hPa (Barometric Range Absolute Pressure Only)
550HB para 550 to 1100 hPa (Barometric Range Absolute Pressure Only)
880HB para 880 to 1100 hPa (Barometric Range Absolute Pressure Only)
Notas: No todas las combinaciones pueden ser válidas. Verifique en la hoja de especificaciones para números de parte válidos
We noticed you are from the US. Visit your local site for regional offers and live support.