Economical DIN Rail Signal Conditioners

CCT Series

Economical DIN Rail Signal Conditioners | CCT Series

Economical DIN Rail Signal Conditioners

349,29 CCT-100

CE
  • Voltage, Current, Frequency, Resistance, Potentiometer, Thermocouple, RTD and Strain Gage Input Modules
  • Integrator Modules Convert Voltage or Current to Frequency
  • Loop Powered Galvanic Isolator Provides 2 kVeff Isolation Between Input and Output
  • Compatible with Standard 35 mm DIN Rail
Transmisores - Ver productos relacionados

Descripción

The CCT series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 0/4 to 20 mA, or 0 to 10 Vdc. The CCT series features a modern housing design, that is easily mounted on standard DIN rails. Connections are safely and securely made, with input and output connections on the opposite sides of the module.

Internal Design
The CCT series is designed using an internal plug-in three module system that provides flexibility in selecting and changing the power supply, input signal and output signal. The units are supplied with 110 Vac power standard, Consult sales for 220 Vac, and 24 Vdc power.

Isolation
The three internal modules in each signal conditioner (signal input, signal output and power supply) are isolated up to 2 kVeff.

Outputs
Each CCT series signal conditioner is available with current and voltage output (only one may be used at a time). Available output types include 4 to 20 mA or 0 to 20 mA (jumper-selectable) and 0 to 10 Vdc.

Standard outputs are linear and proportional to the signal input. Thermocouple input modules feature special circuitry to linearize the output to the actual temperature, and not to the non-linear signal produced by thermocouple sensors.

Specifications
Power: 110 Vac (standard); 220 Vac or 24 Vdc (optional) (±10% tolerance on all power supplies)
Output: 4 to 20 mA and 0 to 10 Vdc standard; 0 to 20 mA via jumper select
Accuracy: ≤0.2% or ≤0.3,%, depending on the model
Response Time: ≤250 ms
Isolation: 2 kVeff
Ripple: ≤0.5%
Bandpass: 1.5 Hz (-3 dB)
Operating Ambient: -10 to 60°C (14 to 140°F)
Storage Ambient: -30 to 80°C (-22 to 176°F)
Temperature Coefficient: ≤0.015%/°C
Power Consumption: 1.5 VA max
Enclosure: Polycarbonate, RAL 7032; UL 94 V-1, IP40 protection
Terminal Housing: Polycarbonate, UL 94-2, IP20 protection
Max Wire Size: 4 mm² (14 AWG)
Dimensions: 75 H x 45 W x 110 mm D (2.95" x 1.77" x 4.33")
Weight: 270 g (0.6 lb)
Mounting: DIN rail 46277 and EN 50022 (35 x 7.5 mm)

Realizar Pedido(Especifique el número de modelo)
Número de pieza/Desc.
Cant.
Descripción
DC Voltage Input
CCT-01-0/100MV
290.75
Stock: 7 semanas
 
0 to 100 mV dc input, 0 to 10 V or 0/4 to 20 mA output
CCT-01-0/1V
296.99
Stock: 1 semana
 
0 to 1 V dc input, 0 to 10 V or 0/4 to 20 mA output
CCT-01-0/10V
307.10
Stock: 1 semana
 
0 to 10 V dc input, 0 to 10 V or 0/4 to 20 mA output
CCT-01-0/100V
296.99
Stock: 1 semana
 
0 to 100 V dc input, 0 to 10 V or 0/4 to 20 mA output
CCT-01-0/650V
307.10
Stock: 7 semanas
 
0 to 650 V dc input, 0 to 10 V or 0/4 to 20 mA output
AC Voltage Input
CCT-08-0/100MV
296.99
Stock: 7 semanas
 
0 to 100 mV ac input, 0 to 10 V or 0/4 to 20 mA output
CCT-08-0/1V
296.99
Stock: 1 semana
 
0 to 1 V ac* input, 0 to 10 V or 0/4 to 20 mA output
CCT-08-0/10V
296.99
Stock: 1 semana
 
0 to 10 V ac* input, 0 to 10 V or 0/4 to 20 mA output
CCT-08-0/100V
247.50
Stock: 7 semanas
 
0 to 100 V ac* input, 0 to 10 V or 0/4 to 20 mA output
CCT-08-0/650V
281.12
Stock: 1 semana
 
0 to 650 V ac* input, 0 to 10 V or 0/4 to 20 mA output
AC Current Input
CCT-04-0/50MA
296.99
Stock: 7 semanas
 
0 to 50 mA ac input, 0 to 10 V or 0/4 to 20 mA output
CCT-04-0/5A
281.12
Stock: 1 semana
 
0 to 5 A ac input, 0 to 10 V or 0/4 to 20 mA output
DC Current Input
CCT-32-0/50MA
296.99
Stock: 1 semana
 
0 to 50 mA dc input, 0 to 10 V or 0/4 to 20 mA output
CCT-32-0/5MA
296.99
Stock: 1 semana
 
0 to 5 mA dc input, 0 to 10 V or 0/4 to 20 mA output
RTD Input
CCT-20-0/100C
314.09
Stock: 1 semana
 
0 to 100°C RTD input, to 10 V or 0/4 to 20 mA output
CCT-20-0/200C
314.09
Stock: 1 semana
 
0 to 200°C RTD input, to 10 V or 0/4 to 20 mA output
CCT-20-0/300C
314.09
Stock: 7 semanas
 
0 to 300°C RTD input, to 10 V or 0/4 to 20 mA output
CCT-20-0/400C
314.09
Stock: 7 semanas
 
0 to 400°C RTD input, to 10 V or 0/4 to 20 mA output
CCT-20-0/500C
314.09
Stock: 7 semanas
 
0 to 500°C RTD input, to 10 V or 0/4 to 20 mA output
CCT-20-0/600C
314.09
Stock: 7 semanas
 
0 to 600°C RTD input, to 10 V or 0/4 to 20 mA output
Resistance/Potentiometer Input
CCT-95-0/200
Consult Sales  
Stock: 
 
 
0 to 200 Ω input, 0 to 10 V or 0/4 to 20 mA output
CCT-95-0/2K
293.16
Stock: 7 semanas
 
0 to 2K Ω input, 0 to 10 V or 0/4 to 20 mA output
CCT-95-0/20K
244.30
Stock: 7 semanas
 
0 to 20 kΩ input, 0 to 10 V or 0/4 to 20 mA output
CCT-95-0/200K
293.16
Stock: 7 semanas
 
0 to 200 kΩ input, 0 to 10 V or 0/4 to 20 mA output
CCT-90
303.12
Stock: 1 semana
 
Potentiometer input, 0 to 10 V or 0/4 to 20 mA output
Frequency Input
CCT-05-40/70
298.37
Stock: 1 semana
 
0 to 40 Hz min range, 0 to 70 Hz max range, 0 to 10 V or 0/4 to 20 mA
CCT-05-70/125
298.37
Stock: 7 semanas
 
0 to 70 Hz min range, 0 to 125 Hz max range, 0 to 10 V or 0/4 to 20 mA
CCT-05-125/225
298.37
Stock: 7 semanas
 
0 to 125 Hz min range, 0 to 225 Hz max range, 0 to 10 V or 0/4 to 20 mA
CCT-05-225/400
298.37
Stock: 7 semanas
 
0 to 225 Hz min range, 0 to 400 Hz max range, 0 to 10 V or 0/4 to 20 mA
CCT-05-400/700
298.37
Stock: 7 semanas
 
0 to 400 Hz min range, 0 to 700 Hz max range, 0 to 10 V or 0/4 to 20 mA
CCT-05-700/1250
298.37
Stock: 7 semanas
 
0 to 700 Hz min range, 0 to 1250 Hz max range, 0 to 10 V or 0/4 to 20 mA
CCT-05-1250/2250
298.37
Stock: 7 semanas
 
0 to 1250 Hz min range, 0 to 2250 Hz max range, 0 to 10 V or 0/4 to 20 mA
CCT-05-2250/4K
298.37
Stock: 7 semanas
 
0 to 2250 Hz min range, 0 to 4 kHz max range, 0 to 10 V or 0/4 to 20 mA
CCT-05-4K/7K
298.37
Stock: 7 semanas
 
0 to 4 kHz min range, 0 to 7 kHz max range, 0 to 10 V or 0/4 to 20 mA
CCT-05-7K/12.5K
298.37
Stock: 7 semanas
 
0 to 7 kHz min range, 0 to 12.5 kHz max range, 0 to 10 V or 0/4 to 20 mA
CCT-05-12.5K/22.5K
298.37
Stock: 7 semanas
 
0 to 12.5 kHz min range, 0 to 22.5 kHz max range, 0 to 10 V or 0/4 to 20 mA
CCT-05-22.5K/40K
298.37
Stock: 7 semanas
 
0 to 22.5 kHz min range, 0 to 40 kHz max range, 0 to 10 V or 0/4 to 20 mA
Strain Gage Input
CCT-80
293.16
Stock: 1 semana
 
Strain gage input, 0-10 V or 0/4 to 20 mA output
Thermocouple Input (common models are show below. Please use the Part Number Builder beneath this table to select other configuration)
CCT-22-0/400C
Consult Sales  
Stock: 
 
 
J thermocouple input, 0-400°C , 0/4 to 20mA output
CCT-23-0/1000C
300.41
Stock: 7 semanas
 
K thermocouple input, 0-1000°C , 0/4 to 20mA output
CCT-24-0/200C
Consult Sales  
Stock: 
 
 
T thermocouple input, 0-200°C , 0/4 to 20mA output
CCT-24-0/300C
300.41
Stock: 7 semanas
 
T thermocouple input, 0-300°C , 0/4 to 20mA output
Loop Powered Isolators
CCT-100
349.29
Stock: 1 semana
 
Loop powered galvanic isolation module
Power Supplies
Todos los precios se muestran en EUR
Notas: *The CCT-08 signal frequency range is 20 Hz to 6KHz. **110 Vac powered units supplied standard. To order 220 Vac or 24 Vdc powered models add “-220VAC” or “-24VDC” to the model number. No charge for 220 Vac, add $50 to price for 24 Vdc.

Referencia del fabricante

Construya su Referencia Abajo
Descripciones de las opciones:


(1) Input Types Seleccione:
01 para DC Voltage
08 para AC Voltage
04 para AC Current
32 para DC Current
22 para Thermocouple Type J
23 para Thermocouple Type K
24 para Thermocouple Type T
25 para Thermocouple Type E
26 para Thermocouple Type S
27 para Thermocouple Type R
20 para RTD
90 para Potentiometer
95 para Resistance
05 para Frequency
80 para Strain Gage
55-V para Voltage
55-I para Current

(2) Input Ranges Seleccione:
-0/100MV para 0 to 100 mV dc (CCT-01 Only)
-0/1V para 0 to 1 V dc (CCT-01 Only)
-0/10V para 0 to 10 V dc (CCT-01 Only)
-0/100V para 0 to 100 V dc (CCT-01 Only)
-0/650V para 0 to 650 V dc (CCT-01 Only)
-0/100MV para 0 to 100 mV ac (CCT-08 Only)
-0/1V para 0 to 1 V ac (CCT-08 Only)
-0/10V para -0/10V ac (CCT-08 Only)
-0/100V para 0 to 100 V ac (CCT-08 Only)
-0/650V para 0 to 650 V ac (CCT-08 Only)
-0/50MA para 0 to 50 mA ac (CCT-04 Only)
-0/5A para 0 to 5 A ac (CCT-04 Only)
-0/50MA para 0 to 50 mA dc (CCT-32 Only)
-0/5MA para 0 to 5 mA dc (CCT-32 Only)
-0/200C para 0 to 200°C (CCT-24 Only)
-0/300C para 0 to 300°C (CCT-23 and CCT-24 Only)
-0/400C para 0 to 400°C (CCT-22 CCT-23 and CCT-24 Only)
-0/500C para 0 to 500°C (CCT-22 and CCT-23 Only)
-0/600C para 0 to 600°C (CCT-22 and CCT-23 Only)
-0/700C para 0 to 700°C (CCT-22 and CCT-23 Only)
-0/800C para 0 to 800°C (CCT-23 and CCT-25 Only)
-0/900C para 0 to 900°C (CCT-23 Only)
-0/1000C para 0 to 1000°C (CCT-23 Only)
-0/1200C para 0 to 1200°C (CCT-23 Only)
-600/1600C para 600 to 1600°C (CCT-26 Only)
-850/1700C para 850 to 1700°C (CCT-27 Only)
-0/100C para 0 to 100°C (CCT-20 Only)
-0/200C para 0 to 200°C (CCT-20 Only)
-0/300C para 0 to 300°C (CCT-20 Only)
-0/400C para 0 to 400°C (CCT-20 Only)
-0/500C para 0 to 500°C (CCT-20 Only)
-0/600C para 0 to 600°C (CCT-20 Only)
Nada (dejar en blanco) para 100 Ohms Min/1 M Ohms Max Input (CCT-90 Only)
-0/200 para 0 to 200 Ohms (CCT-95 Only)
-0/2K para 0 to 2K Ohms (CCT-95 Only)
-0/20K para 0 to 20K Ohms(CCT-95 Only)
-0/200K para 0 to 200K Ohms(CCT-95 Only)
-40/70 para Min Range 0 to 40 Hz. Max Range 0 to 70 Hz. (CCT-05 Only)
-70/125 para Min Range 0 to 70 Hz. Max Range 0 to 125 Hz (CCT-05 Only)
-125/225 para Min Range 0 to 125 Hz. Max Range 0 to 225 Hz (CCT-05 Only)
-225/400 para Min Range 0 to 225 Hz. Max Range 0 to 400 Hz (CCT-05 Only)
-400/700 para Min Range 0 to 400 Hz. Max Range 0 to 700 Hz (CCT-05 Only)
-700/1250 para Min Range 0 to 700 Hz. Max Range 0 to 1250 Hz (CCT-05 Only)
-1250/2250 para Min Range 0 to 1250 Hz. Max Range 0 to 2250 Hz (CCT-05 Only)
-2250/4K para Min Range 0 to 2250 Hz. Max Range 0 to 4 kHz (CCT-05 Only)
-4K/7K para Min Range 0 to 4 kHz. Max Range 0 to 7 kHz (CCT-05 Only)
-7K/12.5K para Min Range 0 to 7 kHz. Max Range 0 to 12.5 kHz (CCT-05 Only)
-12.5K/22.5K para Min Range 0 to 12.5 kHz. Max Range 0 to 22.5 kHz (CCT-05 Only)
-22.5K/40K para Min Range 0 to 22.5 kHz. Max Range 0 to 40 kHz (CCT-05 Only)
Nada (dejar en blanco) para 350 Ohms (CCT-80 Only)
Nada (dejar en blanco) para Ranges varies (CCT-55-V and CCT-I Only)

(3) Power Seleccione:
Nada (dejar en blanco) para 110 Vac Standard
-220VAC para 220 Vac
-24VDC para 24 Vdc
Notas: No todas las combinaciones pueden ser válidas. Verifique en la hoja de especificaciones para números de parte válidos

Manuales del productos:

Descargar CCT-100 - Loop Powered Galvanic Isolator
Descargar CCT-01 CCT04 CCT-08 CCT-32 - Voltage and Current Input Signal Conditioners
Descargar CCT-05 Series - Frequency Input Signal Conditioners
Descargar CCT-20, CCT-90, CCT-95 - RTD, Potentiometer and Resistance Signal Conditioners
Descargar CCT-22 through CCT-27 - Thermocouple Input Signal Conditioners
Descargar CCT-55 Series - Signal Integrators
Descargar CCT-80 Series - Strain Gage Signal Conditioners