Cookies de la web de Omega
Utilizamos cookies en la web. Estas cookies son esenciales para que la web que funcione correctamente. Si sigue sin cambiar la configuración, vamos a suponer que usted está dispuesto a recibir todas las cookies de este sitio web.

Para obtener más información acerca de las cookies, por favor haga clic aquí
Cerrar
Cesta  |  Contacto  | 
En España 800 900 532
Fuera de España(+34) 911 776 121
Layer N Banner

High Accuracy Displacement Transducer/Motion Sensors (LVIT)

LDI-119

High Accuracy Displacement Transducer (LVDT) | LDI-119

High Accuracy Displacement Transducer (LVDT)

635,46 LDI-119-150-A010A

CE
  • Low Cost, Robust Construction
  • Contactless Operation Prevents Wearout from Dithering or Cycling
  • Excellent Stroke-to-Length Ratio
  • 19 mm (0.75") Diameter Housing Sealed to IP67
  • Wide Choice of Range: 25 to 200 mm (1 to 8") Full Scale
  • High Accuracy with Low Linearity Error
  • Radial Cable Exit with Swivel Rod Eye Ends
  • Designed to Operate Under Adverse Temperature, Vibration, Shock, and Humidity Conditions
Sensores y transductores - Ver productos relacionados

Descripción

The LDI-119 Series LVIT (Linear Variable Inductive Transducer) position sensors from are contactless devices designed for factory automation and a variety of industrial and commercial applications such as motor sport vehicles, automotive testing, solar cell positioners, wind turbine prop pitch and brakes, and packing equipment. With their compact device, superior performance, and excellent stroke-to-length ratio, the LDI-119 sensors are ideal for both industrial testing, laboratories, and OEM applications.

LDI-119 sensors are offered in 6 full scale ranges from 25 to 200 mm (1 to 8"). Operating from a variety of DC voltages, these sensors offer a choice of outputs and all include the field programmability calibration feature. LDI-119 products come with radial exiting cable and two swivel rod eye ends for easy installation.

The LDI series also include a larger body version, the LDI-127, for those applications needing a heavier duty unit.

Specifications
Analog I/Os:
    0 to 10V output with 12 to 30V input, 35 mA max;
    4 to 20 mA (3-wire) output with 18 to 30V input,
    60 mA max 75°C (167°F max)
Measuring Range: 25 to 200 mm (1 to 8") full scale
Linearity Error: ±0.15% of Full Scale Output (FSO) typical, ±0.25% max
Resolution: 0.025% of FS
Update Rate: 300 Hz nominal
Operating Temperature: -20 to 85°C (-4 to 185°F)
Temperature Coefficient: 0.015% of FS/degree°C
Vibration: 5 to 20 Hz, 0.5" p-p; 20 to 2000 Hz, 4.2 g p-p
Shock: 1000 g, 11 ms
Terminations: IEC IP67
Humidity: 95% RH, non-condensing
Housing Material: Aluminum
Realizar Pedido(Especifique el número de modelo)
Número de pieza/Desc.
Cant.
Descripción
Anodised Aluminium Housing
0 to 10 Vdc output
LDI-119-025-A010A
499.99
Stock: 1 semana
 
Linear sensor, 25 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-050-A010A
537.03
Stock: 1 semana
 
Linear sensor, 50 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-075-A010A
582.98
Stock: 5 semanas
 
Linear sensor, 75 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-100-A010A
592.07
Stock: 1 semana
 
Linear sensor, 100 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-150-A010A
635.46
Stock: 1 semana
 
Linear sensor, 150 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-200-A010A
662.63
Stock: 1 semana
 
Linear sensor, 200 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
4 to 20 mA output
LDI-119-025-A020A
509.67
Stock: 1 semana
 
Linear sensor, 25 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-050-A020A
537.03
Stock: 5 semanas
 
Linear sensor, 50 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-075-A020A
570.73
Stock: 5 semanas
 
Linear sensor, 75 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-100-A020A
612.20
Stock: 1 semana
 
Linear sensor, 100 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-150-A020A
615.74
Stock: 1 semana
 
Linear sensor, 150 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-200-A020A
640.85
Stock: 1 semana
 
Linear sensor, 200 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
300 Series Stainless Steel Housing
0 to 10 Vdc output
LDI-119-025-A010S
633.76
Stock: 5 semanas
 
Linear sensor, 25 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-050-A010S
687.48
Stock: 5 semanas
 
Linear sensor, 50 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-075-A010S
724.38
Stock: 5 semanas
 
Linear sensor, 75 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-100-A010S
768.04
Stock: 5 semanas
 
Linear sensor, 100 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-150-A010S
848.63
Stock: 5 semanas
 
Linear sensor, 150 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-200-A010S
929.23
Stock: 5 semanas
 
Linear sensor, 200 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
4 to 20 mA output
LDI-119-025-A020S
643.79
Stock: 5 semanas
 
Linear sensor, 25 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-050-A020S
687.48
Stock: 1 semana
 
Linear sensor, 50 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-075-A020S
713.07
Stock: 5 semanas
 
Linear sensor, 75 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-100-A020S
768.04
Stock: 1 semana
 
Linear sensor, 100 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-150-A020S
848.63
Stock: 5 semanas
 
Linear sensor, 150 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-200-A020S
929.23
Stock: 5 semanas
 
Linear sensor, 200 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
Todos los precios se muestran en EUR
We noticed you are from the US. Visit your local site for regional offers and live support.