High Accuracy Displacement Transducer/Motion Sensors (LVIT)

LDI-119

High Accuracy Displacement Transducer (LVDT) | LDI-119

High Accuracy Displacement Transducer (LVDT)

609,55 LDI-119-150-A010A

CE
  • Low Cost, Robust Construction
  • Contactless Operation Prevents Wearout from Dithering or Cycling
  • Excellent Stroke-to-Length Ratio
  • 19 mm (0.75") Diameter Housing Sealed to IP67
  • Wide Choice of Range: 25 to 200 mm (1 to 8") Full Scale
  • High Accuracy with Low Linearity Error
  • Radial Cable Exit with Swivel Rod Eye Ends
  • Designed to Operate Under Adverse Temperature, Vibration, Shock, and Humidity Conditions
Sensores y transductores - Ver productos relacionados

Descripción

The LDI-119 Series LVIT (Linear Variable Inductive Transducer) position sensors from are contactless devices designed for factory automation and a variety of industrial and commercial applications such as motor sport vehicles, automotive testing, solar cell positioners, wind turbine prop pitch and brakes, and packing equipment. With their compact device, superior performance, and excellent stroke-to-length ratio, the LDI-119 sensors are ideal for both industrial testing, laboratories, and OEM applications.

LDI-119 sensors are offered in 6 full scale ranges from 25 to 200 mm (1 to 8"). Operating from a variety of DC voltages, these sensors offer a choice of outputs and all include the field programmability calibration feature. LDI-119 products come with radial exiting cable and two swivel rod eye ends for easy installation.

The LDI series also include a larger body version, the LDI-127, for those applications needing a heavier duty unit.

Specifications
Analog I/Os:
    0 to 10V output with 12 to 30V input, 35 mA max;
    4 to 20 mA (3-wire) output with 18 to 30V input,
    60 mA max 75°C (167°F max)
Measuring Range: 25 to 200 mm (1 to 8") full scale
Linearity Error: ±0.15% of Full Scale Output (FSO) typical, ±0.25% max
Resolution: 0.025% of FS
Update Rate: 300 Hz nominal
Operating Temperature: -20 to 85°C (-4 to 185°F)
Temperature Coefficient: 0.015% of FS/degree°C
Vibration: 5 to 20 Hz, 0.5" p-p; 20 to 2000 Hz, 4.2 g p-p
Shock: 1000 g, 11 ms
Terminations: IEC IP67
Humidity: 95% RH, non-condensing
Housing Material: Aluminum
Realizar Pedido(Especifique el número de modelo)
Número de pieza/Desc.
Cant.
Descripción
Anodised Aluminium Housing
0 to 10 Vdc output
LDI-119-025-A010A
479.61
Stock: 1 semana
 
Linear sensor, 25 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-050-A010A
515.14
Stock: 1 semana
 
Linear sensor, 50 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-075-A010A
559.21
Stock: 5 semanas
 
Linear sensor, 75 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-100-A010A
567.94
Stock: 1 semana
 
Linear sensor, 100 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-150-A010A
609.55
Stock: 1 semana
 
Linear sensor, 150 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-200-A010A
635.62
Stock: 5 semanas
 
Linear sensor, 200 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
4 to 20 mA output
LDI-119-025-A020A
488.89
Stock: 5 semanas
 
Linear sensor, 25 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-050-A020A
515.14
Stock: 1 semana
 
Linear sensor, 50 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-075-A020A
547.46
Stock: 5 semanas
 
Linear sensor, 75 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-100-A020A
587.24
Stock: 1 semana
 
Linear sensor, 100 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-150-A020A
590.64
Stock: 1 semana
 
Linear sensor, 150 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-200-A020A
614.72
Stock: 1 semana
 
Linear sensor, 200 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
300 Series Stainless Steel Housing
0 to 10 Vdc output
LDI-119-025-A010S
607.92
Stock: 5 semanas
 
Linear sensor, 25 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-050-A010S
659.46
Stock: 5 semanas
 
Linear sensor, 50 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-075-A010S
694.85
Stock: 5 semanas
 
Linear sensor, 75 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-100-A010S
736.72
Stock: 5 semanas
 
Linear sensor, 100 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-150-A010S
814.03
Stock: 1 semana
 
Linear sensor, 150 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-200-A010S
891.34
Stock: 5 semanas
 
Linear sensor, 200 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
4 to 20 mA output
LDI-119-025-A020S
617.55
Stock: 5 semanas
 
Linear sensor, 25 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-050-A020S
659.46
Stock: 5 semanas
 
Linear sensor, 50 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-075-A020S
684.00
Stock: 5 semanas
 
Linear sensor, 75 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-100-A020S
736.72
Stock: 5 semanas
 
Linear sensor, 100 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-150-A020S
814.03
Stock: 5 semanas
 
Linear sensor, 150 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-200-A020S
891.34
Stock: 5 semanas
 
Linear sensor, 200 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
Todos los precios se muestran en EUR