 - Discontinued Tri-Axial Transient Shock Data Logger

OM-CP-TSR101-50

 | OM-CP-TSR101-50

CE
  • 3-Axis Shock Recorder
  • Built-In Accelerometers
  • Measures Dynamic and Static Acceleration
  • Programmable Start Time
  • Compact and Reusable
  • Optional Password Protection
  • High Speed Download (115,200 baud)
Registradores de datos - Ver productos relacionados

Descripción

The OM-CP-TSR101 series has been discontinued. Please see the OM-CP-SHOCK-SERIES as a possible alternative or contact our Sales department.

The OM-CP-TSR101 is a battery powered, stand alone 3-axis shock data logger. The OM-CP-TSR101 measures and records instantaneous shock levels when the user-selectable shock levels have been exceeded. There are 15 rates to chose from ranging from 1024 to 1 Hz.

The OM-CP-TSR101 is valuable in characterizing environments such as packaging and fragility assessment (drop testing), break and crash testing, and shipping validation. This is an all-in-one compact, portable, easy to use device that will measure and record approximately 349,000 measurements per axis.

The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. The device can be started and stopped directly from your computer and its small size allows it to fit almost anywhere.

The OM-CP-TSR101 makes data retrieval quick and easy. Simply plug it into an empty COM or USB port and our user-friendly software does the rest.

Specifications
Channels:
Shock (3-axis)
Acceleration Type: MEMS semiconductor
Reading Rate Range: 15 options from 0.976 ms/1024 Hz
to 1 second, selectable in software
Trigger Specifics: User settable trigger levels on X, Y, and/or Z axis,
and specifies # of samples after triggers
Pre-Trigger Specifics: Records a pre-trigger of up to 50 readings
prior to the trigger point
Frequency Response: 0 Hz to approx. 400 Hz (50, 100 g)
[0 to 512 Hz (5 g)]
Real Time Recording: May be used with PC to monitor
and record instantaneous acceleration in real time (only at 1 second rate,
not possible during logging)
Start Modes: Software programmable, immediate start
or delay start up to 180 days in advance
Password Protection: An optional password may be programmed into the device
to restrict access to configuration options. Data may be read out without the password
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Power: 9 V lithium or alkaline battery (included), user replaceable
Battery Life: 7 days typical with lithium battery, immediate start, 1024 Hz
Data Format: Date and time stamped, G and mG
Time Accuracy: ±1 minute per month at 20 to 30°C
Computer Interface: USB or serial interface (cable required) 115,200 baud
Software:
Operating Environment: -20 to 60°C (-4 to 140°F) 0 to 95% RH non-condensing
Dimensions: 89 H x 112 W x 26 mm D (3.5 x 4.4 x 1.0")
Weight: 340 g (12 oz)
Material: Anodized aluminum
Realizar Pedido(Especifique el número de modelo)

¿Qué compraron otras personas?: Cuando se muestre este icono, haga clic para expandir una lista de los productos que otras personas adquirieron al comprar ese modelo.

Número de pieza/Desc.
Cant.
Descripción
Click to expand/minimize a list of what others bought with theOM-CP-IFC200
OM-CP-IFC200
€168.91
Stock: En stock
 
Windows software and 3.5 m USB interface cable
Click to expand/minimize a list of what others bought with theOM-CP-BAT103
OM-CP-BAT103
€42.51
Stock: 1 semana
 
Replacement 9V lithium battery
Todos los precios se muestran en EUR
Notas: Comes with complete operator’s manual and 9V lithium battery. The OM-CP-IFC110 Windows software includes RS-232 cable required to operate the data logger (software sold separately).
We noticed you are from the US. Visit your local site for regional offers and live support.